Matters installation should pay attention to the autoclave
Autoclave should be placed in the room. When equipped with multiple autoclave, should be placed separately. Each operating room should have direct access to an outdoor outlet or channel shall ensure that the location is well ventilated. Pretending autoclave kettle lid should be prevented between the autoclave kettle body kettle lid sealing surface bump each other. When the lid was fixed position carefully on the kettle body, tightening the main nut must be diagonally symmetrically in multiple progressively tightened. Force should be uniform, not allowed kettle lid tilted to one side, in order to achieve a good seal. Pros and cons of the coupling nut, except for positive and negative rotating nut, two arcuate sealing surface can not be relatively rotating, all coupling nut pattern when assembled, should be coated with oil. Valve needle seal line, just gently turn the valve needle, the pressure close the cover, you can achieve a good seal. Hand drive moving rotors on the autoclave, check the operation is flexible. The controller should be flat on the operating table, the working environment temperature is 10-40 ℃, relative humidity less than 85%, the surrounding medium does not contain conductive dust and corrosive gases. Check the panel and the rear panel of the movable member and the fixed contact is normal, pulling open the top cover, check socket contact is loose, and whether there is transportation damage caused by improper care or corrosion. Reactor controller should be grounded. Connect all wires, including electric power cable line, the controller and the autoclave between electrical lines and temperature sensors and tachometer wires. The panel "Power" total air switch is closed, the DRO should be displayed.
DRO settings on a good variety of parameters (such as the upper limit alarm temperature, operating temperature, etc.) and then press the "heating" switch, an electric furnace is turned on, and the "heating" indicator light on the switch. Adjust the "surge" knob, you can adjust the electric heating power. (For electric heating of the autoclave) Press the "stirring" switch, stirring motor power, while "stirring" light switch on the light, slowly rotating the "Speed" knob, slowly rotating the motor, observe whether the motor is forward, when correct, the belt hang down, and then restart. After the operation, allowing autoclave natural cooling, water cooling or stent placed over the cold. After the temperature drop, and then release the gas under pressure in the autoclave and the pressure reduced to atmospheric pressure (pressure gauge shows zero), then the main nut symmetrical equal Loosen, then remove the main nut, then carefully remove the tank lid, placed on the bracket. Each time the operation is completed, should be cleared autoclave kettle body, kettle cover residues. Main sealing ports should be regularly cleaned and kept clean and not allowed to wipe the autoclave with a hard object or surface asperities.
Jiangsu Qiulin Special Equipment Joint Stock company is a listed company on Cryogenic equipment, mineral ball miller line and non-standard presure on oil/gas /chemical industry. It has two brother company: Jiangsu Qiulin Port Machinery,Co.,Ltd, and Shenghui Light Steel structure co., mainly on steel structure fabrication.Qiulin is professional air separation plant, LNG plant, cryogenic storage system and gas relevant equipments supplier. We provide the best service obsess over customer's demand...

Navigation List Company Profile Products News Equipment Certificate Contact

Contact us TEL :00-86-510-86268020 FAX :00-86-510-86268021 MOBILE :00-86-13961609160 E-MAIL :heidi@jsqiulin.com Office Add :No.30.33,Yuexiang road,Yuecheng Town,Jiangyin City,Jiangsu Province,China 苏icp备05029643号